Data Center Maintenance
Did you know that up to 90% of unexpected data center incidents are caused from electrical and mechanical cooling systems? Without proper maintenance contracts, your data center may be the next to experience an unplanned event. These events get noticed – and quickly. They drive your operating costs through the roof and reduce your center’s overall efficiency rating. Worse – all eyes immediately focus on you. Keystone Critical System can put you in a positive light and we have the track record to prove it.
Do you have qualified air conditioning technicians servicing your Computer Room A/C Systems? We do, and we have over 30 years dedicated to keeping these highly specialized systems up on running.
Today’s equipment requires an advance level of technical expertise to maintain the high levels of reliability necessary to meet IT demands.
Key advantages of Keystone’s CRITICAL SITE MANAGEMENT SERVICE:
In-house Mechanical and Electrical Engineering: Many solutions for proper maintenance require application engineering skill sets. This avoids repetitive repairs for an application-oriented issue. Additionally, Keystone’s Information Technology application engineering overview is to analyze your entire site environmental system including utility feed, generator, ATS, power distribution, cooling, fire suppression, interlocking controls, physical room integrity and confirms the viability of the overall system synergy.
Our SITE MANAGEMENT SERVICE can provide a solution to manage all your environmental systems, just the cooling system or anywhere in between. Our SITE MANAGEMENT SOLUTIONS are site specific and custom fit to meet your needs.
OVERALL SITE SOLUTION may include the following:
- UPS & Battery Service Contracts
- Generator Service Contracts
- Clean Agent and Sprinkler Service Contracts
- UPS Battery Replacements
- Ground Integrity Testing
- Vibration Testing
- Power Quality Analysis and Reporting
- Equipment Failure Forensics
- Site Integrity Review of Equipment Meeting Manufacturer’s Specifications
- System Integration and Confirmation Testing
- 24/7/365 Reliability
COOLING
Trained and Skilled Technicians: Keystone strives to provide continuous training for our technicians in maintaining and repairing CRAC systems. Properly trained and skilled technicians supported by in-house engineering and available parts provide client critical system support unmatched by any other CRAC agency in South Florida.
Parts Availability: Keystone inventories more Liebert CRAC parts than any other service company performing Liebert CRAC service in South Florida. Mean Time To Repair (MTTR) is greatly reduced when parts are readily available.
- All technicians certified to work on CRAC systems.
- Service vans include a full inventory of Liebert CRAC system factory parts.
- Condenser fan motors, both variable and constant speed
- Condenser fan speed controller
- High and low pressure switches for both Deluxe and DS models
- Condenser fan blades
- Compressor and reheat contactors
- Full array of fuses
- Infra-red humidifier light bulbs
- Humidifier sump float
- Factory condensate pumps, 480V
- Fan belts
UPS Battery Replacement
Life expectancy of UPS batteries can vary greatly. When it is time for replacement, Keystone offers services to remove and replace the battery, while also disposing of the old battery properly.
AC Maintenance
Data Center HVAC systems should be cool and run efficiently. Proper maintenance from Keystone will have the system performing reliably, prevent failures and reduce downtime.
Data Center Cleaning
Data Center cleaning reduces contamination, improves efficiency, and protects sensitive equipment. Regular scheduled cleanings are critical to a well maintained facility, which ensures the equipment and employees are protected against harmful contaminants.
Power Quality Analysis
Power complications to your sensitive equipment will cause havoc and reliability issues if not addressed quickly. Keystone has power quality measurement equipment to perform the recording and technical analysis.
Load Bank Testing
Many times your electrical back up equipment such as UPS and generator operate at a low percentage of its full load capacity. A full load capacity test can assure the generator will operate when you need it the most.
Vibration Testing Consulting
Predictive maintenance with vibration analysis and thermal imaging is just what you need to prevent the next unexpected failure.
UPS & Battery Service Contracts
Keystone Critical Systems offers a wide range of service contracts to maintain your UPS system, batteries, DC power plant and other critical power equipment. Our programs include both preventive maintenance and on-call emergency service needs.
Generator Service Contracts
Because backup systems sit idle for prolonged periods of the time, regularly scheduled maintenance is crucial to ensure a smooth transition when they are called upon to maintain critical buss.
Clean Agent / Pre-Action & Sprinkler Systems
Clean agent suppression systems are a key component for fire suppression in mission critical faculties. When a fire breaks out within data center, water would be fine if the safety of the occupants in the facility or destroying millions of dollars of electronics wasn’t an issue, but it is.
Equipment Failure Forensics
By conducting a series of tests, measuring power quality, measuring vibration and evaluating thermal images in combination with reviewing the equipment application Keystone has the experience to get to the root cause of reoccurring problems. By remedying the underlying issue(s), re-occurrence of failures is prevented and overall operating efficiencies are improved.